High pressure rotary and reciprocating tribometer

Tribometers under pressurized or gas environment

AMT supplies speical tribometers with a high pressure chamber for experiments under hydrogen, high pressure and other gases. 

TE 58 High Pressured Rotary Tribometer

The TE 58 is a hermetically sealed high-pressure rotary tribometer, designed to operate at pressures up to 15 MPa with conventional refrigerants or CO2 as the pressurizing gas/fluid.

The TE 58 has servo controlled loading with force transducer feedback, servo motor with encoder feedback for speed control, SUPERSLIM Serial Link Interface Module and COMPEND 2000 Window compatible control and data acquisition software. The machine is floor-standing.

Technical Specifications

  • Maximum Torque: max. 10Nm
  • Maximum Load: 5000N
  • Maximum Pressure: 15MPa
  • Maximum Speed: 1200rpm
  • Maximum Temperature: 120C

If you want to have further information or would like to submit a demo test, please contact us.

TE 59 Induced Motion Autoclave Fretting Rig

TE 59 Induced Motion Autoclave Fretting Tribometer  incorporates a simple, two-part, miniature autoclave, comprising a base plate and an upper body, mounted on a voice coil actuator. Specimen tooling and pipe connections are mounted on the base plate, leaving the upper body free to be removed, allowing the system to be set up and tested open.

Technical Specifications

  • Maximum water temperature: 220°C
  • Maximum pressure: 24 bar
  • Maximum contact load: 2 N
  • Stroke: 20 to 200 microns
  • Frequency: 20 to 60 Hz
  • Maximum working temperature: 250°C
  • Design Temperature: 300°C

If you want to have further information or would like to submit a demo test, please contact us.

TE 60 High Pressure Hydrogen Reciprocating Tribometer

The TE 60 is a three-station reciprocating tribometer, designed around a high pressure chamber, for experiments under hydrogen and other gases. It includes a vacuum pump for purging the chamber before charging with a chosen gas, so can also be used for tests under medium vacuum. Facilities are provided for running tests with plate specimen temperatures from -55°C to +150°C.

Technical Specifications

  • Gases: Hydrogen, Argon, CO2
  • Working Pressure: 0.1 mbar to 120 bar
  • Stroke Range: 0-20mm
  • Frequency: 0-5Hz
  • Motion: Sinusoidal
  • Load Range: 5-50N
  • Temperature Rating: -55°C to 150°C

If you want to have further information or would like to submit a demo test, please contact us.

Questions?

We are happy to help!

Phone (Beijing): +86 10 5975 5440

Phone (Nanjing): +86 25 58281023-1625/1623

Fax: +86 10 5975 5441
E-Mail: info@china-amt.com
Adress (Beijing): Building 33D608, Huilongsen Science and Technology Park, Beijing BDA, Beijing, 101111

Adress (Nanjing): Block B-1617, Jiyin building, 211 Pubin Resaerch and Delevopement Park, Jiangbei, Nanjing, 211800​